Electrical Configuration Matrix (Model 120)
|
|
|
|
|
|
|
A,B
|
Flying Leads, 22 Awg,
|
CE (Low Voltage)
|
Weathertight
|
Economical Configuration
|
|
C,D
|
1/4" NPT, Flying Leads, 22 Awg,
|
CE (Low Voltage)
|
NEMA 4X
|
Most Economical NEMA 4X Configuration
|
|
E,F
|
1/2" Conduit, Flying Leads, 18 Awg.
|
CE (Low Voltage), CSA /UL Div 2
|
NEMA 4X
|
Great Option for Hazardous Locations
|
|
G.H
|
Terminal Strip, Access for Conduit Hub or Cable Grip
|
CE (Low Voltage)
|
NEMA 4X
|
Best Protection for Gauge and switch. Entire product is enclosed in NEMA enclosure
|
|
L,M
|
Plug-In Connector DIN 43650
|
CE(Low Voltage)
|
NEMA 4X Connector (IP65)
|
Connector CSA/UL approved for general purpose wiring. Field Wireable. Very popular option.
|
|
J,K
|
1/2" Conduit, Flying Leads, 18 Awg
|
CSA / UL Class I, Division I, Groups C & D, Class II, Divison I, Groups E,F & G
|
NEMA 7, with optional NEMA 4X
|
Explosion-proof design. Externally adjustable switch set points.
|
|
|
|
|
|
|
REED SWITCH RATINGS (Resistive Load)
|
|
|
|
|
|
Option:
|
E ,F,G
|
H
|
A
|
|
†Power
|
60 W
|
60 W
|
3W
|
|
Max. Current
|
3.0 Amps
|
1.0 Amps
|
0.25 Amps
|
|
Max. Voltage VAC/VDC
|
240
|
240
|
125
|
|
Setting ( %F.S.)
|
25 to 95
|
25 to 100
|
10 to 90
|
|
Hysteresis (Max/Nom)
|
15% / 8% (F.S.)
|
20% / 13% (F.S.)
|
10% / 5% (F.S.)
|
|
Repeatability
|
1% F.S.
|
1% F.S.
|
1% F.S.
|
|
Leads 22 Awg. (per switch)
|
(2), 24"
|
(3), 24"
|
(3), 24"
|
† Product of the switching voltage and current shall not exceed the power rating of the device.