Model 140/142 Div 2 Hazardous Locations

"Diaphragm Type"

 Differential Pressure Switch / Transmitter
Electrical Configurations E, F & W
Class l, Division 2, Groups A, B, C & D
Class ll, Division 2, Groups F & G

Certifications:

  • CSA Certified to Canadian and US Standards

Dimensions:       

 See 140_dimension_haz_loc

Contact Us Today For Availability

Product Features/Benefits

  • Indication and Pressure Containing Element design identical to Standard product
  • Lower Cost when Compared to Explosion-proof designs
  • CSA Listed to Canadian and US Standard (Switch and transmitter)
  • Ranges, Scales, Dial Sizes, Ports, Elastomers etc. available are equivalent to Non-Hazardous Location product
  • Hermetically Sealed Switch Design
  • Aluminum Weatherproof NEMA 4X Electrical Enclosure
  • Field Wireable Terminal Strip (Separate Junction Box not required)
  • No Input Power required to operate the switches
  • For complete model details See BULLETIN_140, BULLETIN_142
  • Installation and Operation Manual (Refer to Hazardous Locations section. Electrical Configurations E, F, or W) ELECIOM_142 and ELECIOM_140

Specifications / Configuration

  • Working Pressures Hazardous Locations Model 140:
    Aluminum 3000 PSIG; End Connections Limited to  2000 PSIG;   NACE 1625 PSIG
    Brass 1500 PSIG Not Available with End Connections
    Stainless Steel: 3000 PSIG; End Connections 2000 PSIG;  NACE 1625 PSIG
  • Working Pressures Hazardous Locations Model 142:
    1375 PSIG (95 bar)  Al, Brass, SS  (End, Back & Bottom) NACE Included
  • Operating Temp:
    Switches: -40°F to +200°F (-40°C to +93°C)
    Transmitter: -20°F to 150°F (-29°C to 65°C)

Electrical Specifications:

See Bulletin:  Specificationsheet_140Specificationsheet_142.     Refer to  Electrical  Configurations E & F, & W


Switch Electrical Specifications: See Bulletin: ELECIOM_140, ELECIOM_142

Mid-West Hazardous Locations Indicating / Non-indicating  switch (Electrical Configurations E or F) is intended for use in Division 2 hazardous Locations.

  • 1 or 2 Independently adjustable SPST or SPDT Switches
  • Weather-proof Aluminum NEMA 4X Rated enclosure with ½”FNPT Conduit
  • Field Wireable Terminal Strip – Wire range 22Awg to 16 Awg
Type SPST (Normally Open) SPDT
*Power 25 Watt 3 Watt
Maximum Current 0.5 Amps 0.25 Amps
Maximum Voltage 240 VAC/VDC 125 VAC/VDC
Switch Setting
%Full Scale
15 to 90 (140)
15 to 90 (142)
15 to 90 (140)
15 to 90 (142)
Hysteresis
Maximum/Nominal
15% / 8%
Full Scale
10% / 5%
Repeatability 1% Full Scale 1% Full Scale

Transmitter Specifications: See Bulletin: ELECIOM_140, ELECIOM_142 (Electrical Configuration W)Transmitter Configuration “W”, Model 140/142 Transmitter is intended for use in Division 2 locations (W electrical configuration). The Model 140/142 indicating / non-indicating differential pressure transmitter is a 2 wire loop powered microprocessor based 4-20 ma transmitter. The magnetic angle sensor & electronics senses the angle (relative to the transmitter sensor) of the magnet which moves linearly in the bore. Each transmitter is individually calibrated to the gauge using an 11 point calibration linearization technique. This method results in a <2% full scale accuracy for the upper 80% of the range.

  • 4-20mA Loop Powered Micro Processor based Transmitter
  • 4 Position Terminal Strip 22 AWG – 16 AWG
  • 8-28 VDC Loop Powered 2-wire interface
  • 1000 Ohm max loop resistance at 28 Vdc.
  • ±2% Accuracy from 20% to 100% of scale, ascending
  • Indicator operation is isolated from Loop Power
  • Weather-proof Aluminum NEMA 4X Rated enclosure with ½”FNPT Conduit

The Mid-West Advantage

“Piston Type” Hazardous Locations Product

Model No. Differential Pressure Range Accuracy Working Pressure Electrical Available Specifications Installation/ Operation Manual Electrical IOM Drawing
Model 120 0-5 PSID to 0-110 PSID ±3/2/3% Up to 6,000 PSI CE / LVD, RoHS Compliant, NEMA 4X, Flying Leads / DIN Connector, Class 1-Div. 1, Class 1-Div. 2
Model 121 0-5 PSID to 0-100 PSID ±3/2/3% Up to 6,000 PSI CE / LVD, RoHS Compliant, NEMA 4X,Terminal Strip, Class 1-Div. 2, 4-20mA Transmitter N/A
Model 220 0-5 PSID to 0-100 PSID ±3/2/3% Up to 4,000 PSI CE / ATEX / RoHS Compliant, KOSHA CERTIFIED, NEMA 4X, Terminal Strip, Class 1-Div. 1, Class 1-Div. 2, 4-20mA Transmitter N/A

“Diaphragm Type” Hazardous Locations Product

Model No. Differential Pressure Range Accuracy Working Pressure Electrical Available Specifications Installation/ Operation Manual Electrical IOM Drawing
Model 130 0-5" H2O to 0-15 PSID (0-400" H2O) 0-5" H2O to 0-9.9" H2O
±5%
0-10" H2O to 0-15 PSID
±3/2/3%
Up to 500 PSI CE / LVD, RoHS Compliant, NEMA 4X, Class 1-Div. 1
Model 140 0-50" H2O to 0-100 PSID 0-50" H2O to 0-399" H2O
±5%
0-15 PSID to 0-100 PSID
±3/2/3%
Up to 3,000 PSI CE / LVD, RoHS Compliant, NEMA 4X, Terminal Strip, Class 1-Div. 1, Class 1-Div. 2, 4-20mA Transmitter
Model 142 0-20" H2O to 0-25 PSID ±3/2/3% Up to 3,000 PSI CE / LVD, RoHS Compliant, NEMA 4X, Terminal Strip, Class 1-Div. 2, 4-20mA Transmitter
Model 240 0-20" H2O to 0-100 PSID ±3/2/3% Up to 1500 PSI CE / ATEX / RoHS Compliant CSA, UL & KOSHA CERTIFIED, NEMA 4X, Terminal Strip, Class 1-Div. 1, Class 1-Div. 2, 4-20mA Transmitter N/A